Title Adaptive spectral Doppler estimation
Authors Fredrik Gran, Andreas Jakobsson, Jörgen Jensen
Full-text Available as PDF, Restricted Access
Alternative Location http://ieeexplore.ieee.org/..., Restricted Access
Alternative Location http://dx.doi.org/10.1109/T..., Restricted Access
Publication IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Year 2009
Volume 56
Issue 4
Pages 700 - 714
Document type Article
Status Published
Quality controlled Yes
Language eng
Publisher IEEE
Abstract English In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence. The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to provide good spectral resolution and contrast even when the observation window is very short. The 2 adaptive techniques are tested and compared with the averaged periodogram (Welch's method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set of matched filters (one for each velocity component of interest) and filtering the blood process over slow-time and averaging over depth to find the PSD. The methods are tested using various experiments and simulations. First, controlled flow-rig experiments with steady laminar flow are carried out. Simulations in Field II for pulsating flow resembling the femoral artery are also analyzed. The simulations are followed by in vivo measurement on the common carotid artery. In all simulations and experiments it was concluded that the adaptive methods display superior performance for short observation windows compared with the averaged periodogram. Computational costs and implementation details are also discussed.
Keywords common carotid artery, adaptive spectral estimation, spectral Doppler ultrasound, temporal resolution, data acquisition sequence, power spectral density, blood power spectral capon method, matched filters, blood amplitude and phase estimation technique, steady laminar flow, pulsating flow, femoral artery,
ISBN/ISSN/Other ISSN: 08853010

Questions: webmaster
Last update: 2013-04-11

Centre for Mathematical Sciences, Box 118, SE-22100, Lund. Telefon: +46 46-222 00 00 (vx)